Search for PARI Report/Technical Note
Steel Corrosion Monitoring for RC Deck of Open Type Wharf by embedded sensor
Publication year | Port and Airport Research Institute Technical Note 1294 2014.12 |
---|---|
Author(s) | Shiniciro OKAZAKI, Ema KATO, Yuichiro KAWABATA, Mitsuyasu IWANAMI |
Department /Divison |
Structural Engineering Field Structural Mechanics Group |
Executive Summary | Port facilities are generally located in severe environments.Therefore, their structural performance is often easily degraded owing to material deterioration and corrosion.To keep their performance above the required level, effective and efficient maintenance should be carried out.In this study, focusing on upgrading and optimizing maintenance of port concrete facilities,we tried developing the deterioration judgment method used by electrochemical properties of reinforced concrete (RC) members.The RC specimens, in which corrosion sensors were installed, were exposed to sea water splashing environment.The corrosion sensor can detect the initiation of corrosion and corrosion rate by monitoring half-cell potential and polarization resistance. |
PDF File | /en/pdf/en/No.1294.pdf |